Melody JP104 Water Ionizer ¹q¸Ñ¤ô¾÷
Eng
ªF¬v¬ì§Þ¦³¤½¥qªº³Ì·s ´Ú¦¡. ¤º¸m0.01·L¦Ì¬õ¥~½uÂo¤ô¨t²Î.
HK$8500
Melody JP104
¬OªF¬v¬ì§Þ¦³¤½¥qªº³Ì·s²£«~.¬O¦a²y¤W²Ä¤@³¡¸Ë¸m¤F¦³¥Íª«¥ÛªºÂo¤ô¨t²Î.·í±µÄ²¤ô®É,¥Íª«¥Û¯àÄÀ©ñ¥XtÂ÷¤l.
Áú°ê¹ª«ºÞ²z§½(FDA)µý®Ñ
¦³¥|ºØ¤£¦PÆP©ÊÂ÷¤l¤ô¥i¨Ñ¿ï¾Ü .
¦³¥|ºØ¤£¦Pªº»Ä©ÊÂ÷¤l¤ô¥i ¨Ñ¿ï¾Ü .
»yµ³qª¾¤£¦PpH Ȫº¹q¸Ñ¤ô¿é¥X
¥i¿ï¥Î¥u¦³Âo¤ô¥\¯à,¦Ó¤£¥Î¹q¸Ñ¥\¯à.
Âo¤ß¥i¥Î¤E¨ì¤Q¤GÓ¤ë,¬Ý¥Î¶q¦Ó©w.
¥þ·L«¬¹q¸£±±¨î
²G´¹ÅéÅã¥ÜÂo¤ß¹Ø©R
§ó´««Ü®e©ö,¥u»Ý¤@¤ÀÄÁ
¹qÀ£: 220V ac
¯Ó¹q¶q: 110W,5A
«¶q: 4.5kg / 10lbs
¤Ø¦T: 265 x 145 x 328 mm
¿é¥X²v: 3 litre/min
¤J¤ô¤ôÀ£: .7-5kg/ccm
¤J¤ô¤ô·Å: 5-30C
²M¬~¨t²Î: ¥þ¦Û°Ê¤Î¤H¤u¾Þ§@
¹q¸Ñ·¥: ¤¶ô¥Õª÷¶y,65mmX109mmX0.5mm,¤j·§¥i¥Î20
¦~.
Y¤J¤ô·Å«×¹L°ª®É,·|¦Û°ÊÃö³¬.
¤£ù׿û¥X¤ôºÞ
¤@¦~ì¼t«O¾i
¤U¸ü JP104
Melody ¹q¸Ñ¤ô¤ô¾÷ªº¨Ï¥ÎªÌ»¡©ú®Ñ
Oxidation-Reduction Potential and pH:
Ionized Level
O.R.P.
pH
Tap Water
+ 10mV
7.0
Level 1 alkaline
-165mV
8.7
Level 2 alkaline
-185mV
9.7
Level 3 alkaline
-215mV
10.3
Level 4 alkaline
-248mV
10.8
Purified Water
-20mV
7.2
Super Oxide (Acid)
+65mV
4.5
BEST O.R.P.
-90mV to -250mV
Alkaline minerals present:
Mineral
Tap Water
After Ionization
Alkaline
After Ionization
Acidic
Calcium
17.0 mg/litre
20.0 mg/litre
8.0 mg/litre
Magnesium
5.0 mg/litre
5.5 mg/litre
3.0 mg/litre
Sodium
12.0 mg/litre
15.0 mg/litre
3.0 mg/litre
Potassium
2.0 mg/litre
3.8 mg/litre
1.3 mg/litre
Tap Water
Alkaline water
Alkaline water
Acidic water
Acidic water
Bacteria
After Electrolysis
1 Hour later
After Electrolysis
1 Hour later
1400
120
0
0
0
Alkaline minerals present:
Mineral
Tap Water
After Ionization
Alkaline
After Ionization
Acidic
Calcium
17.0 mg/litre
20.0 mg/litre
8.0 mg/litre
Magnesium
5.0 mg/litre
5.5 mg/litre
3.0 mg/litre
Sodium
12.0 mg/litre
15.0 mg/litre
3.0 mg/litre
Potassium
2.0 mg/litre
3.8 mg/litre
1.3 mg/litre
Tap Water
Alkaline water
Alkaline water
Acidic water
Acidic water
Bacteria
After Electrolysis
1 Hour later
After Electrolysis
1 Hour later
1400
120
0
0
0
Report of Analysis by Certified
Laboratories:In this test, a
specially concocted ¡§brew¡¨ containing over-limit
quantities of every commonly detected dangerous
chemical was passed through a Jupiter Ionizer.
The results show that contaminants were reduced
in most cases to levels undetectable by the
performing labs. Test Laboratories: Seoul
Metropolitan Government Institute of Health and
Environment, Korea; Mizutek, USA; Microbac
Laboratories, USA; Brandywine Science Center.(Note:
Eliminated indicates that no modern device can
detect it within its range)
Contaminant
Standard mg /
litre
Result mg /
litre
KmnO4
10.0
2.7
Lead
0.05
Eliminated
Fluoride
1.5
Eliminated
Arsenic
0.05
Eliminated
Cyanide
0.01
Eliminated
Mercury
0.001
Eliminated
Selenium
0.01
Eliminated
Chromium
(6+)0.05
NOT Found
Cadmium
0.01
NOT Found
Phenol
0.005
NOT Found
Diazinon
0.02
NOT Found
Malathion
0.25
NOT Found
Parathion
0.06
NOT Found
Fenitrothion
0.04
NOT Found
1,1,1 Trichloroethane
0.1
NOT Found
Tetrachloroethylene
0.03
NOT Found
Dichloromethane
0.02
NOT Found
Benzene
0.01
NOT Found
Xylene
0.5
NOT Found
1,1 Dichloroethylene
0.03
NOT Found
Carbon Tetrachloride
0.002
NOT Found
Methylene Chloride
25.0ppm
5.0ppm
Nitrate
10.0
1.82
Iron
0.3
<0.02
Manganese
0.05
<0.02
Sodium
20.0
8.0
Measurement
Improvement in
ionized water over tap water
pH
34% increase
Calcium
43% increase
Magnesium
9% increase
Sodium
20% increase
Potassium
14% increase
Total alkalinity
100% increase
Electrical conductivity
24%
ORP
100-200% decrease (i.e. more
antioxidizing)
JP104¹q¸Ñ¤ô¤ô¾÷ªº¦w¸Ë
VIDEO
VIDEO
VIDEO